Excess micromotion. A static stray field pushes the ion off the trap axis, away from the RF null where the RF field vanishes. The ion settles where the static force balances the time-averaged RF force, but there the RF field is not zero, so the ion is shaken at the RF frequency. This driven motion is called excess micromotion, and its amplitude is about (q/2) times the displacement.
Cooling cannot remove it. Turn on friction and press "Settle onto the equilibrium orbit": the slow secular motion dies away but the ion keeps oscillating at the RF frequency. Raising the compensation slider cancels the stray field with extra electrodes, which brings the ion back to the null and makes the micromotion vanish. This is how experiments null it.
An oscillating quadrupole field cannot trap a charge with a static potential alone (Earnshaw), but the rapidly alternating saddle gives a net force towards the axis, so the ion is confined.
Motion is bounded only when both x and y are stable (green region of the stability diagram). For a = 0 this needs q < 0.908. Inside it the ion makes a slow secular oscillation at ω ≈ βΩ/2 with fast micromotion at Ω.
For fixed voltages, q and a scale as 1/Ω². Raising the RF frequency moves the operating point towards the origin of the stability diagram: the ion is held more weakly, so the secular motion slows and the micromotion shrinks. Lowering it can push the ion out of the stable region.
Friction (for example collisions with a buffer gas) removes energy, so the ion spirals towards the axis. It also enlarges the stable region: points just outside the green area can become bounded.
Rods: red = positive potential, blue = negative. Shaded square: potential energy of a positive ion (red = high, blue = low), tilted by any stray field. Dashed circle: r = r₀. Cross: the equilibrium position; teal line: the micromotion orbit about it (shown only with a stray field on).
The height of the surface is the ion's potential energy U = ½A(τ)(x² − y²), so the ion rolls downhill exactly as the quadrupole force pushes it. The saddle flips every half RF cycle: the ion is pushed towards the centre along one axis while it slides away along the other, and the flapping turns this into a net restoring force. Drag to rotate; height is scaled to the largest saddle.