The four RF rods confine the ion radially (x, y) as in sim33. Two ring electrodes at the ends carry a static DC voltage that repels the ion, giving a harmonic well along the axis (z).
A static potential cannot trap in all three directions, so the endcap field that confines z must push the ion outward in x and y. This shifts both radial a-parameters by −2κ, which is why strong axial confinement eats into radial stability (watch the green region move).
The axial motion is a slow, undamped harmonic oscillation (az = 4κ). Friction damps all three axes and the ion settles at the centre of the trap.
Drag to rotate. RF rods are tinted by their instantaneous potential (red = positive, blue = negative); the two end rings carry the static endcap voltage. The dashed ring marks r = r₀ at the ion's axial position.