A single ion is cooled, driven coherently on the S–D qubit transition, and read out by fluorescence. The experiment repeats shot after shot to estimate the probability of finding the ion in D.
Doppler cooling (397 nm + 866 nm) scatters photons on S–P and cools the ion to a few tens of motional quanta. Sideband cooling (729 nm red sideband, with 854 nm to quench D5/2) then removes quanta one at a time down to the motional ground state.
The clock laser (729 nm, on the carrier) rotates the qubit between S1/2 and D5/2: for a cold ion, a pulse of area θ leaves it in D with probability sin²(θ/2). A π pulse transfers it fully.
Without sideband cooling the ion stays at the Doppler limit (⟨n⟩ ≈ 16). Its motion shifts the Rabi frequency from shot to shot (Lamb–Dicke parameter η = 0.1 assumed), so the Rabi flopping loses contrast, most visibly for large pulse areas.
Detection (397 nm + 866 nm) makes an ion in S fluoresce (bright) while an ion in D5/2 stays dark. Each shot gives one random outcome; many shots give P(D).
Durations are not to scale. 866 nm and 854 nm are infrared; their beams are drawn in false colour.
Click or drag on the timeline to jump within the shot. Bars show which laser is on in each phase.
Each detection window adds one entry. Bright shots (ion in S) cluster at high counts, dark shots (ion in D5/2) near zero. Counts at or below the threshold are read out as dark. The line is the expected distribution for the current P(D).