An oscillating quadrupole field cannot trap a charge with a static potential alone (Earnshaw), but the rapidly alternating saddle gives a net force towards the axis, so the ion is confined.
Motion is bounded only when both x and y are stable (green region of the stability diagram). For a = 0 this needs q < 0.908. Inside it the ion makes a slow secular oscillation at ω ≈ βΩ/2 with fast micromotion at Ω.
For fixed voltages, q and a scale as 1/Ω². Raising the RF frequency moves the operating point towards the origin of the stability diagram: the ion is held more weakly, so the secular motion slows and the micromotion shrinks. Lowering it can push the ion out of the stable region.
Friction (for example collisions with a buffer gas) removes energy, so the ion spirals towards the axis. It also enlarges the stable region: points just outside the green area can become bounded.
Rods: red = positive potential, blue = negative. Shaded square: potential energy of a positive ion (red = high, blue = low). Dashed circle: r = r₀.
The height of the surface is the ion's potential energy U = ½A(τ)(x² − y²), so the ion rolls downhill exactly as the quadrupole force pushes it. The saddle flips every half RF cycle: the ion is pushed towards the centre along one axis while it slides away along the other, and the flapping turns this into a net restoring force. Drag to rotate; height is scaled to the largest saddle.